4. Test Report Number 132579 Issue 1 Page 4 of 8 Fig 1 : Photograph showing the condition of the Sample p rior to Salt Spray Test Fig 2: Photograph showing the condition of the Sample after 72 hours Salt Spray Test

5. Test Report Number 132579 Issue 1 Page 5 of 8 Fig 3: Photograph showing the condition of the Sample af ter 144 hours Salt Spray Test Fig 4: Photograph showing the condition of the Sample after 240 hours Salt Spray Test

6. Test Report Number 132579 Issue 1 Page 6 of 8 Fig 5: Photograph showing the condition of the Sample after 3 3 6 hours Salt Spray Test Fig 6: Photograph showing the condition of the Sample after 504 hours Salt Spray Test

7. Test Report Number 132579 Issue 1 Page 7 of 8 Fig 7 : Photograph showing the condition of the Sample after 6 72 ho urs Salt Spray Test Fig 8 : Photograph showing the condition of the Sample after 6 72 hours Salt Spray Test

8. Test Report Number 132579 Issue 1 Page 8 of 8 Fig 9 : Photograph showing the condition of the Sample after 6 72 hours S alt Spray Test

2. Test Rep ort Number 132579 Issue 1 Page 2 of 8 144 – 168 Hours The sample showed evidence of moderate yellow corrosion product and total white zinc corrosion (see photograph after 144 ). 240 – 312 Hours The sample showed a small area of red ferrous corros ion on the tube arm adjacent to the nut and a significant amount small spots of red ferrous corrosion 1.0mm maximum size and significant yellow corrosion product and total white zinc corrosion (see photograph after 240 hours ). 336 Hours The sample showed a small area of red ferrous corrosion on the tube arm adjacent to the nut 20mm x 10mm and small area on the left hinge. The general condition of the sample showed a significant amount of small spots of red ferrous corrosion 1.0mm maximum size and a significant amount of yellow corrosion product and total white zinc corrosion , the spring tension mechanism function worked satisfactory (see photograph after 336 hours). 408 – 504 Hours The sample showed an area of red ferrous corrosion on the tube arm adjacent to the nut and small area on the left hinge. The general condition of the sample showed a n significant - almost total amount of small spots of red ferrous corrosion 2 .0mm maximum size and a significant - almost total amount of yellow corrosion product and total white zinc corrosion (see photograph after 504 hours). 576 – 6 4 8 Hours The sample showed an area of red ferrous corrosion on the tube arm adjacent to the nut and small area on the left hinge. The general condition of the sample showed a significant amount of small spots of red ferrous corrosion 2 .0mm maximum size and a significant amount of yellow corrosion product and total white zinc corrosion . 6 72 Hours The sample showed an area of red ferrous corrosion on the tube arm adjacent to the nut and small area on the left hinge. The general condition of the sample showed a significant amount of small spots of red ferrous corrosion 3 .0mm maximum size and a significant amount of yellow corrosion product and total white zinc corrosion , the spring tension mechanism function worked satisfactory (see photograph s).

3. Test Report Number 132579 Issue 1 Page 3 of 8 COMMENTS / CONCLUSION Bef ore the salt spray test , the spring tension mechanism function worked satisfactory. After completing 33 6 hours salt spray test, the spring tension mechanism function worked satisfactory. After completing 672 hours salt spray test, the spring tension mech anism function worked satisfactory. There are no pass or failure criteria defined within the standard in relevant information, this is a matter of agreement between the parties concerned. The finish applied to the Galvanised Steel / Tube Assembly Sample tested, failed to withstan d 672 hours Salt Spray Test requirement without the formation of red ferrous corrosion. END OF TEXT

1. REPORT COMPILED BY REPORT APPROVED BY G B Withers G B Withers Corrosion Science Technician Corrosion Science Technician TESTS MARKED “NOT UKAS ACCREDITED” IN THIS REPORT/CERTIFICATE ARE NOT INCLUDED IN THE UKAS ACCREDITATION SCHEDULE FOR OUR LAB ORATORY. TESTS MARKED ‘SC’ HAVE BEEN SUBCONTRACTED. OPINIONS AND INTERPRETATIONS EXPRESSED HEREIN ARE OUTSIDE THE SCOPE OF UKAS A CCREDITATION. THIS TEST REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT WRITTEN APPROVAL OF THE LABORATORY. RESULTS IN THIS REPORT RELATE ONLY TO THE ITEMS TESTED. Our Ref: GBW Number 1 325 7 9 Issue 1 Date 3 0 / 03 / 20 1 5 Page 1 of 8 A/C No: T004 Tested For: - KEE SAFETY LOGISTICS LTD Unit A2, Cradley Business Park Overend Road Cradley Heath West Midlands B64 7DW SALT SPRAY TESTING OF GALVANISED STEEL PLAT E / TUBE ASSEMBLY SAMPLE INTRODUCTION The finished sample was submitted to the laboratory for Salt Spray T esting in accordance with the relevant specification. RELEVANT INFORMATION Description / Finish : 1 off . Galvanised Steel / Tube Assembly Sam ple Specification: Salt Spray Test in accordance with ASTM B117 - 11 Test Duration: 33 6 – 672 Hours Exposure Submitted By: Phil Higgs Purchase Order No. : STD419142 Sample Rec eipt Date: 26 / 02 /2015 RESULTS Salt Spray Test ( ASTM B117 - 11 ) The photograph in fig 1 is showing the sample prior to test, the sample was then exposed to a neutral 5% S a l t Spray for a t est period of 33 6 and 672 hours, examination s after 72 hours and then every 24 hours, revealed the following observations: - Galvanised Steel / Tube Assembly Sample 72 Hours The sample showed evide nce of total white zinc corrosion (see photograph). LABORATORY : - MOXLEY INDUSTRIAL CENTRE, WESTERN WAY, ADDRESS WEDNESBURY, WEST MIDLANDS, WS10 7BG TEL: 0121 505 4050 FAX: 0121 505 1115 www.rotechlabs.co.uk info@rotechlabs.co.uk LABORATORIES LIMITED 0366 Test Report