Dokumentation
Ose_directory e-shot
2727 Visninger •Checkline II maintenance manual
3093 Visninger •Chemsplash Pro WD40 Test
2442 Visninger •Ergonomi 2006
3023 Visninger •Ose_directory Suspension harness
2757 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3464 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3242 Visninger •VISOR Installation steps
4010 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
3002 Visninger •Hearing protection 3M
2555 Visninger •Statistik for arbejdsmiljø 2014
3021 Visninger •LOTO_GuideBook_Europe_English
2563 Visninger •Remote area lighting system
2323 Visninger •Isol8 - The Ultimate Absorbent for Spills
2329 Visninger •Magazine Arbejdsmiljø - november 2012
2507 Visninger •KEE_DOME_MINI
2424 Visninger •TDS Speedglas 9100
2599 Visninger •The Pocketbook of Lean Visuals
2584 Visninger •Instructional video Sign holder
1880 Visninger •PREMARK installation manual
2556 Visninger •D-S CSR Håndbog
17124 Visninger •Find handskestørrelse - størrelsesguide for handsker
10096 Visninger •3M jupiter manual
6186 Visninger •9100 Manual
5146 Visninger •D-S 70 års om os brochure
4792 Visninger •EN 388 nye mærkninger forklaring
4756 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4698 Visninger •Faldsikring flyer
4388 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
4068 Visninger •VISOR Installation steps
4010 Visninger •Guide til valg af åndedrætsværn
3605 Visninger •TR-300 Bruger manual
3569 Visninger •VARMEX 2000 Fordele
3561 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3464 Visninger •3M TR 300 PAPR training video
3460 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3242 Visninger •Procedure for iklædning af engangsbeklædning
3201 Visninger •3020 Solcreme SPF 30 datablad
3167 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3156 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3125 Visninger •1728570 EVAMASQUE_UK
Visninger | |
---|---|
941 | Totale visninger |
0 | Medlemmer visninger |
941 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
1. Product Sheet – Escape range EVAMASQUE filt E ring ES c A p E d EV ic E r Ef. : 17 285 70 d escription The EVAMASQUE is a 15 min filtering escape device which provides an effective protection during the evacuation of accidentally polluted areas which volume of oxygen in atmosphere is more than 17%. It is particularly suited to the conditions of use in oil and gas and chemical industries due to its broad spectrum gas filtration coverage with the ABEK filter. It is also compatible with other items of PPE such as spectacles or helmets. The EVAMASQUE filtering escape device is safe, practical and easy to use. It is small, neatly packed in a robust protective casing to be carried or stored easily for long period of times, up to 12 years (4 years without maintenance, 12 years with 2 filter changes). The EVAMASQUE filtering escape device ensures maximum protection for escape situations. It is only intended for use in emergency situations. Benefits • Effective protection. • Light and Compact. • Quick and Easy to use. • Excellent visual comfort. Standards • EVAMASQUE : DIN 58647-7 Respiratory protective devices for self-rescue, Part 7: Filtering devices for self-rescue. c haracteristics • Size : One size. • Storage time : 12 years with 2 filter changes (filter shelf life : 4 years without maintenance). • Storage conditions : • n et Weight : 365g • d imensions of product :15,5 x 10 x 8 cm • p ackaging : - Individually packed 15 x 11,5 x 11,5 cm - Shipping box : 50 units • n ominal p rotection f actor ( npf ) : 50 • Material - Mask moulded in Black EPDM, equiped with Neopren inhalation Valve, Silicone exhalation valves and elastomeric strap. - Filter : Carbone, Paper and non-woven PA. - Casing : Red Polystyren. - Adhesive tape.
2. Honeywell Safety Products Unit 3 Elmwood - Chineham Park - Basingstoke - RG24 8WG - United Kingdom Phone: +44 (0) 1256 693 200 - Fax: +44 (0) 1256 693 300 Email: info-uk.hsp@honeywell.com Maintenance • Main components can be changed. • For details please refer to the user manual. • Part numbers for maintenance : f ilt E r c A p A city A ccording to th E din 58647-7 S t A nd A rd f ilter t ype t est gas t est gas concentration in air Minimum breakthrough time of class Vol. -% mg/l 15 min A Cyclohexane (C6H12) 0.25 8.7 15 B Chlorine (Cl2) 0.25 7.4 15 B Hydrogen sulphide (H2S) 0.25 3.6 15 B Hydrogen cyanide (HCN) 0.25 2.8 15 E Sulphur dioxide (SO2) 0.25 6.7 15 K Ammonia (NH3) 0.25 1.8 15 B Hydrogen sulphide (H2S) 1.0*) 14.2 5 (*) To estimate the gas filter’s breakthrough safety, it is also tested with 1.0 Vol. -% sulphur dioxide. Test conditions 30L/mn, 70% relative humidity, 20°C 3 1 2 4 p roduct Use Cleaning : • Clean the half mask with warm soapy cloth, not under running water. • Carefully dry before putting it back to storage. User’s instructions • Make sure that the transport box is not damaged. Warnings : • Do not use the filtering escape device if an effective face seal cannot be achieved. Refer to Maintenance Instructions. • The seal of the filtering escape device is also affected by size and facial structure of the user, e.g. beard hair, etc. • Do not remove the filtering escape device before leaving the contaminated area. • The filtering escape device provides limited protection against low boiling point solvents • The filtering escape device provides limited protection against high concentrations of hazardous substances (The filtration duration will be reduced, or filter can become inefficient at very high concentrations). • Do not use filtering escape devices in tanks and confined spaces wher e there is a risk of oxygen deficiency • The filtering escape device is designed for use in escape situations only . Please consult the supplier if you have any doubt as to whether the respirator is suitable for the situation in which you intend to use it. • Leave the area as soon as the vapour or odour of the contaminants becomes noticeable. The filter is «saturated». It has to be changed. • Not efficient against carbon monoxide (CO). N° Part Numbers Description 1 17 285 02 EVAMASQUE half-mask alone (no filter, no casing) 2 17 285 71 ABEK replacement anti-gas filter with replacement elastic strap + seal ribbon 3 17 799 93 Protective shell with belt clip and clamp 4 17 288 21 Adhesive tape - 50 meters 4 (allows for sealing of about 90 units) 17 266 02 Desinfecting wipes (x100) 1 3 2 4 3
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.