Dokumentation
Ose_directory e-shot
2708 Visninger •Checkline II maintenance manual
3080 Visninger •Chemsplash Pro WD40 Test
2430 Visninger •Ergonomi 2006
3002 Visninger •Ose_directory Suspension harness
2743 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3445 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3225 Visninger •VISOR Installation steps
3999 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2984 Visninger •Hearing protection 3M
2542 Visninger •Statistik for arbejdsmiljø 2014
3004 Visninger •LOTO_GuideBook_Europe_English
2546 Visninger •Remote area lighting system
2305 Visninger •Isol8 - The Ultimate Absorbent for Spills
2316 Visninger •Magazine Arbejdsmiljø - november 2012
2496 Visninger •KEE_DOME_MINI
2408 Visninger •TDS Speedglas 9100
2582 Visninger •The Pocketbook of Lean Visuals
2576 Visninger •Instructional video Sign holder
1867 Visninger •PREMARK installation manual
2538 Visninger •D-S CSR Håndbog
17070 Visninger •Find handskestørrelse - størrelsesguide for handsker
10049 Visninger •3M jupiter manual
6150 Visninger •9100 Manual
5107 Visninger •D-S 70 års om os brochure
4760 Visninger •EN 388 nye mærkninger forklaring
4737 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4677 Visninger •Faldsikring flyer
4334 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
4042 Visninger •VISOR Installation steps
3999 Visninger •Guide til valg af åndedrætsværn
3586 Visninger •TR-300 Bruger manual
3550 Visninger •VARMEX 2000 Fordele
3540 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3445 Visninger •3M TR 300 PAPR training video
3429 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3225 Visninger •Procedure for iklædning af engangsbeklædning
3183 Visninger •3020 Solcreme SPF 30 datablad
3157 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3144 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3113 Visninger •APM-135-Product-Manual-Issue-6
Visninger | |
---|---|
369 | Totale visninger |
0 | Medlemmer visninger |
369 | Offentlige visninger |
Del via email
Venligst login for at dele dette presentation via email.
Indlejr på din hjemmeside
1. APM 135 PRESSURE METER OPERATING INSTRUCTIONS Crowcon Detection Instruments 172 Brook Drive, Milton Park , Abingdon, Oxfordshire OX14 4SD Tel: 01235 557780 e mail: sales@crowcon.com web: www.anton bycrowcon .com INSTRUMENT APPLICATION This instrument is not suitable for use with corrosive substances or cyclic hydrocarbons, e.g. motor oil, transmission fluid and Freon. To use the APM 135 with these components, isolation must be provided in the form of a buffer, such as a mineral oil or dry air. INSTRUMENT OPERATION BATTERIES ON / OFF Press and hold button for 0.5s to turn on. Press and hold button for 2s to turn off. Automatic switch - off after 5 minutes, unless any button is activated or the pressure level is above 1 mbar. BACKLIGHT Press button to turn backlight on/off. OUT OF RANGE If the pressure exceeds the positive scale range Out will appear on the display. If the pressure exceeds the negative scale range - Out will appear on the display. ZEROING In order to achieve maximum accuracy it is recommended to zero the instrument in the orientation it will be used before taking any measurements. Ensure both ports are open to atmosphere, and then press the ZERO button which will adjust the reading to zero. UNITS OF PRESSURE Press UNIT button to select required units of pressure. Chosen units will be sav ed when the instrument is switched of f . 1. Positive pressure input spigot 2. Negative pressure input spigot 3. Backlit 4 - digit LCD screen 4. Pressure units selection button 5. Min/Max mode selection button 6. LCD backlight on/off button 7. Power button 8. Z ero pressure button Indicates full battery level. Indicates low battery level and batteries require replacing. Insert 3 AA batteries .
2. MIN/MAX The MIN/MAX operation is used to record the maximum pressure level, minimum pressure level and the difference between the minimum and maximum pressure levels. The first press of the MIN/MAX button displays the maximum pressure recorded. The MAX icon is shown on the display The next press of the MIN/MAX button displays the minimum pressure recorded. The MIN icon is shown on the display. The next press of the MIN/MAX button displays the difference between the minimum and maximum pressure. The MAX - MIN icon is shown on the display. The next press of the MIN/MAX button returns to the standard pressure display. Pressing the ZERO button when either MAX , MIN or MAX - MIN disp lays are shown, only resets the current MIN and MAX values. It does not zero the current pressure reading. Example : Input pressure is 20 mbar, MIN mode selected then press ZERO button. MIN mode shows 20 mbar, MAX mode shows 20 mbar, MAX - MIN mode shows 0 mb ar. During 3 minute wait pressure initially increases to 20.2 mbar then drops to 18.8 mbar. MIN mode shows 18.8 mbar, MAX mode shows 20.2 mbar, MAX - MIN mode shows 1.4 mbar. BATTERY REPLACEMENT 1. Remove the protective rubber boot by slipping it away from the bottom of the case and sliding it over the pressure spigots exposing the case back. 2. Remove the battery cover from the bottom of the case by removing the four screws. 3. Remove the three AA batteries and replace with good quality AA Alkaline batteries taking care to install them the right way round. 4. Replace the battery cover carefully making sure it is alligned properly and replace the screw s . Take care not to over tighten the screws otherwise it may damage the case. 5. For best results and longer life alw ays u se quality alkaline batteries MN 1500 or equivalent. CAUTIONS Exposure to silicone based products, corrosive gases, water / condensation and freezing should be avoided at all times as this will cause damage to the sensor and internal component corrosi on. This instrument should not be stored or operated outside of its operating temperature range. Particular care must be taken not to exceed the maximum pressure ratings for the device as this may rupture the sensor membrane. This is not covered by the manufacturer’s warranty. NOTE: The differential/gauge instruments will only measure positive pressures i.e. positive pressure applied to positive port, or negative pressure applied to the negative port. WARRANTY This instrument is guaranteed against defects of workmanship and materials for a period of twelve months from date of invoice . During the warranty period a defective instrument will be repaired or replaced at the discretion of the manufacturer. This warranty does not cover damage or failure du e to misuse or accident. Modification, adjustment or any alteration shall void the warranty. For any warranty claims to be considered the instrument must be returned to Anton along with proof of purchase at the senders cost. FCC Compliance NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a co mmercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. STANDARD ACCESSORIES The APM 135 is supplied complete with: • Three AA Alkaline batteries • Operating instruction s • Protective rubber boot SPECIFICATIONS Power Supply 3 x AA Alkaline Batteries Battery Life > 100 hours* Duty Cycle Continuous. Auto switch off after 5 mins. Operating Temperature - 10 to +50 °C Weight 360 grams including batteries Dimensions 185 x 75 x 37 mm Accuracy ±2% of reading * Using recommended Industrial batteries Units APM 135 mbar - 39.99 to +19.99 +20.0 to +130.0 PSI - 0.29 to +1.89 mmHg - 15.00 to +19.99 +20.0 to +98.1 mmH 2 O - 199.9 to +199.9 +200 to +1336 inH 2 O - 8.03 to +52.63 hPa - 39.99 to +19.99 +20.0 to +130.0 Pa - 400 to 9999 kPa - 1.99 to 13.00
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.