1. WWW.CLEANSPACETECHNOLOGY.COM Unit 5, 39 Herbert Street, St. Leonards NSW 2065 Australia T: +612 8436 4000 sales@ cleanspacetechnology.com FIND THE RIGHT CLEANSPACE FILTER This table is a guide to assist filter selection based on the application and hazard 1 . IMPORTANT: Users should refer to the Material Safety Data Sheet (MSDS) and establish the hazard concentration before selecting a filter. INDUSTRY APPLICATION HAZARD RIBBON FILTER TYPE CLEANSPACE FILTER CODE Construction Cutting, grinding: Concrete, cement, stone, brickwork Crystalline Silica & concrete, stone, plaster dust P3 PAF-0035 & PAF-0037 Applying insulation: Glass & mineral fiber Particles and fibres P3 PAF-0035 & PAF-0037 Spraying & varnishing: Anti-fouling lacquers, lacquers and synthetic lacquers, water-soluble and solvent based paints, bleaching agents, tar, latex paints, paint remover and wood preservatives Particles & vapours A1P3 & A2P3 PAF-0050 & PAF-0077 (EU ONLY) Metal Work Cutting, grinding, drilling metal (with ventilation) Metallic or rust powder (Conc Dependant) P3 PAF-0035 & PAF-0037 Soldering (without paste) Smoke particles P3 PAF-0035 & PAF-0037 Soldering (with paste) Gases & Ammonia ABEK1P3 PAF-0052 (EU) & PAF-0076 (AU) Welding MIG, TIG, STICK: Aluminium (with ventilation) Aluminium oxide, smoke, ozone P3 PAF-0035 & PAF-0037 Welding MIG, TIG, STICK: Aluminium (with limited ventilation) Aluminium oxide, smoke, ozone ABE1P3 PAF-0051 (EU) & PAF-0091 (AU) Welding MIG, TIG, STICK: Galvanised & Stainless Steel Metallic powder, metal oxide smoke ABE1P3 PAF-0051 (EU) & PAF-0091 (AU) Welding MIG, TIG, STICK: Steel Metallic powder, metal oxide smoke P3 PAF-0035 & PAF-0037 Paint Work Grinding: Paint, lacquers and anti corrosion paint (inc chromium) Fine paint particles P3 PAF-0035 & PAF-0037 Spraying & varnishing: Anti-fouling lacquers, lacquers and synthetic lacquers, water-soluble and solvent based paints, bleaching agents, tar, latex paints, paint remover and wood preservatives Particles & vapours A1P3 & A2P3 PAF-0050 & PAF-0077 (EU ONLY) Spraying & painting: Anti-moulds Organic vapour and mist A1P3 & A2P3 PAF-0050 & PAF-0077 (EU ONLY) Spraying & varnishing: isocyanates Solvent vapour and paint particles (Conc. Dependant) SUPPLIED AIR NA Powder coating Fine paint particles P3 PAF-0035 & PAF-0037 Wood Work Sanding & scraping removal: Paint, polyester resin, lacquers & adhesive (inc chromium based) Fine paint particles P3 PAF-0035 & PAF-0037 Solvent removal: Paint, resin, adhesive Solvent vapour A1P3 & A2P3 PAF-0050 & PAF-0077 (EU ONLY) Flame cleaning: Paint and adhesives Gases, vapours, smoke, fine particles ABE1P3 PAF-0051 (EU) & PAF-0091 (AU) Cutting, planing, drilling: Wood (inc beechwood & oak) Wood dust particles P3 PAF-0035 & PAF-0037 Gluing: solvent based substances (inc polyester or epoxy resin spray) Adhesive mists and solvent vapours (Conc. dependant) A1P3 & A2P3 PAF-0050 & PAF-0077 (EU ONLY) Fibreglass Preparing & applying: Epoxy and polyester resin, amine and anhydride hardener; Glass fibre, dust resin and styrene vapour Methyl ethyl ketine peroxiide (MEKP), styrene vapour A1P3 & A2P3 PAF-0050 & PAF-0077 (EU ONLY) Preparing and spraying fibreglass moulds Organic vapour and mist A1P3 & A2P3 PAF-0050 & PAF-0077 (EU ONLY) Maintenance & Cleaning Disinfection & cleaning: UNKNOWN WASTE Organic vapour, mist, dust ABEK1P3 PAF-0052 (EU) & PAF-0076 (AU) Disinfection & cleaning: Agents containing acids Acids ABE1P3 PAF-0051 (EU) & PAF-0091 (AU) Disinfection & cleaning: Agents containing aldehydes Organic vapour, inorganic vapour, formaldehyde, mist, dust ABE1P3 PAF-0051 (EU) & PAF-0091 (AU) Disinfection & cleaning: Moulds Organic vapour and mist A1P3 & A2P3 PAF-0050 & PAF-0077 (EU ONLY) Healthcare & Laboratories Collection & Handling: Biological material Particles or mist P3 PAF-0035 & PAF-0037 Disinfection & Cleaning: Agents Acids, Aldehydes or specimen preservation Organic vapour, inorganic vapour, specimen preservation, mist, dust or Acids ABE1P3 & AXTM2P2 PAF-0051 (EU), PAF-0091 (AU) & PAF-0087 (EU & AU) Agriculture Cleaning: Animal pens & feed systems (silos) Dust particles P3 PAF-0035 & PAF-0037 Handling & spraying: Pesticide, fungicides, herbicides or organic vapours Vapour, mist and dust ABEK1P3 PAF-0052 (EU) & PAF-0076 (AU) Handling: Liquid Manure or agrochemicals Organic gas and vapours produced by solvents with a boiling point ≤ 65 °C s ABEK1P3 & AXTM2P2 PAF-0051 (EU), PAF-0091 (AU) & PAF-0087 (EU & AU) Handling & Transport Sulphur dioxide Sulphur dioxide ABE1P3 PAF-0051 (EU) & PAF-0091 (AU) Hydrochloric Acid Hydrochloric Acid ABE1P3 PAF-0051 (EU) & PAF-0091 (AU) Liquid Manure Liquid Manure ABEK1P3 PAF-0052 (EU) & PAF-0076 (AU) Ammonia Ammonia ABEK1P3 PAF-0052 (EU) & PAF-0076 (AU) Bacteria and spores Bacteria and spores P3 PAF-0035 & PAF-0037 Formaldehyde Formaldehyde AXTM2P2 PAF-0087 (EU & AU) HAZARDOUS Goods storage/transport HAZARDOUS Goods storage/transport ABEK1P3 PAF-0052 (EU) & PAF-0076 (AU) Fumigation - AX Methyl Bromide AXTM2P2 PAF-0087 (EU & AU) Construction materials Formaldehyde AXTM2P2 PAF-0087 (EU & AU) 1) CleanSpace Technology accepts no liability for incorrect choice of respiratory protective equipment. This chart is only an outline. It is designed to assist in the selection of the most appropriate filter for particular applications. It should not be used as the only means of selecting respirator/filter combination. This guide does not release the user from the obligation to comply with national application regulations and laws and is not a substitute for adhering to and understanding the product instruction manuals. For selection of the correct respiratory protection equipment for your application, consult a safety specialist. IMPORTANT NOTE: Filtering respiratory protection devices should not be used in poorly ventilated areas or confined spaces, such as tanks, small rooms, tunnels or vessels. CleanSpace respirators should not be used in oxygen deficient or oxygen enriched atmospheres or flammable or explosive environments. NE002556

app-image

To install this Web App in your iPhone/iPad press pwa-icon and then Add to Home Screen.

Sikkerhed for alle

Hold dig sikkert opdateret med seneste nyheder og viden indenfor PPE og arbejdsmiljø