3. Test Report Number 1 37009 Issue 1 Pag e 3 of 4 Fig 1 : Photograph showing the condition of the 33.7 x 250mm Tube Sample p rior to Salt Spray Test Fig 2: Photograph showing the condition of the 33.7 x 250mm Tube Sample

4. Test Report Number 1 37009 Issue 1 Pag e 4 of 4 Fig 3 : Photograph showing the condition of the 33.7 x 250mm Tube Sample after 2 16 hours Salt Spray Test Fig 4 : Photograph showing the condition of the 33.7 x 250mm Tube Sample after 2 16 hours Salt Spray Test (corrosion spot)

2. Test Report Number 1 37009 Issue 1 Page 2 of 4 33.7 x 250mm Tube Sample 2 4 – 16 8 Hours The tube sample showed no evide nce of corrosion or deterioration of the finish ( see photograph after 216 hours ). 19 2 – 2 16 Hours The tube sample showed evide nce of one spot of red ferrous corrosion adjacent to the end cap, no other part of the tube sample showed evide nce of corrosion or deterioration of the finish ( see photograph s after 216 hours ). COMMENTS / CONCLUSION There are no pass or failure criteria defined within the standard in relevant information, this is a matter of agreement between the parties concerned. The finish applied to the 33.7 x 250mm Tube Sample tested, withstoo d 2 16 hours Salt Spray Test requirement without significant breakdown . END OF TEXT

1. REPORT COMPILED BY REPORT APPROVED BY G B Withers G B Withers Corrosion Science Technician Corrosion Science Technician TESTS MARKED “NOT UKAS ACCREDITED” IN THIS REPORT/CERTIFICATE ARE NOT INCLUDED IN THE UKAS ACCREDITATION SCHEDULE FOR O UR LABORATORY. TESTS MARKED ‘SC’ HAVE BEEN SUBCONTRACTED. OPINIONS AND INTERPRETATIONS EXPRESSED HEREIN ARE OUTSIDE THE SCOPE OF UKAS ACCREDITATION. THIS TEST REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT WRITTEN APPROVAL OF THE LABORATORY. RE SULTS IN THIS REPORT RELATE ONLY TO THE ITEMS TESTED. Our Ref: GBW Number 1 37009 Issue 1 Date 22 / 05 / 20 1 5 Page 1 of 4 A/C No: T004 Tested For: - KEE SAFETY LOGISTICS LTD Unit A2, Cradley Business Park Overend Road Cradley Heath West Midlands B64 7DW SALT SPRAY TESTING OF Y ELLOW POWDERCOAT TUBE SAMPLE INTRODUCTION The finished sample was submitted to the laboratory for Salt Spray T esting in accordance with the relevant specification. RELEVANT INFORMATION Description : 1 off . 33.7 x 250mm Tube Sample Finish : Yellow Polyester Powdercoat / Zn Primer / Steel Spec ification: Salt Spray Test in accordance with ASTM B117 - 11 Test Duration: 2 16 Hours Exposure Submitted By: Phil Higgs Purchase Order No. : STD419474 Sample Rec eipt Date: 1 2 / 05 /2015 RESULTS Salt Spray Test ( ASTM B117 - 11 ) The photograph s in fig 1 & 2 are showing the tube sample prior to test, the tube sample was then exposed to a neutral 5% S a l t Spray for a t est period of 21 6 hours, examination s after every 24 hours, revealed the following observations: - Pre – Test Assessment showed a number of seeds on the surface finish. LABORATORY : - MOXLEY INDUSTRIAL CENTRE, WESTERN WAY, ADDRESS WEDNESBURY, WEST MIDLANDS, WS10 7BG TEL: 0121 505 4050 FAX: 0121 505 1115 www.rotechlabs.co.uk info@rotechlabs.co.uk LABORATORIES LIMITED 0366 Te st Report