7. Kee Safety Gate Date: 21 st May 2015 Report Reference: 056 - 15 Document No. RS004 Revision 0 3 Issue No. 01 Page 7 of 7 Pictures showing datum point before and after test

5. Kee Safety Gate Date: 21 st May 2015 Report Reference: 056 - 15 Document No. RS004 Revision 0 3 Issue No. 01 Page 5 of 7 Picture of Sample Sample as received and in good condition Test Method The gate as supplied was bolted to a 100mm x 75mm timber support and mounted in the test machine . The test rig operating arm was set to act centrally against the edge of the gate body to which a nylon pad was fixed. The arm travel was adjusted to open the ga te through a minimum angle of 90 de grees at which point the arm returned to its start position allow ing the gate to close under its own spring return. The cycle was then repeated . A datum point was marked to measure any gate drop and opening force was measured pre and post test Test rig se ttings were as follows; Force applied through operating arm - 50N maximum Cycle speed - 4 cycles per minute Reference velocity (opening) - Approximately 0.5m/s Rest time in ope n position - 2 seconds Opening angle - 93 degrees Test Equipment Used Equipment No. Description LEN 126 Door cycle test rig LEN 163 Force gauge LEN 176 Steel rule

4. Kee Safety Gate Date: 21 st May 2015 Report Reference: 056 - 15 Document No. RS004 Revision 0 3 Issue No. 01 Page 4 of 7 Origin of Request Client Details Company Name Kee Safety Logistics Limited Address Unit 2 Cradely Business Park Overend Road Cradely Heath West Midlands Post Code B64 7DW Contact Phil Higgs – Technical & Supplier Quality Manager Order Details Order Number STD419461 Dated 6 th May 2015 Test Details Sample Details Product Safety Gate Model Number Marking / Brand Manufacturer Kee Safety Logistics Limited Date of Manufacture Not known Other information None Test Specification / Details Durability test of 50,000 cycles generally in accordance with BS6375 - 2 clause 6.5 – Resistance to repeated opening & closing Date samples received 7 th May 2015 Date test commenced 8 th May 2015 Date test c ompleted 21 st May 2015 Job Number 2015 - 066 Any special test requirements None

6. Kee Safety Gate Date: 21 st May 2015 Report Reference: 056 - 15 Document No. RS004 Revision 0 3 Issue No. 01 Page 6 of 7 Test Results Test Requirement Actual Assessment Resistance to repeated opening and closing 50,000 cycles 50,000 cycles Pass Force required to open gate pre test – 2.5N (measured centrally on the stop plate) Force required to open gate post test – 2.1N (measured centrally on the stop plate) Gate drop recorded post test – 0.5mm (measured on the top of the stop plate) Disposal The sample wil l be retained for a minimum period of one week prior to disposal Pictures Sample mounted in rig and on test

2. Kee Safety Gate Date: 21 st May 2015 Report Reference: 056 - 15 Document No. RS004 Revision 0 3 Issue No. 01 Page 2 of 7 CONTENTS Authorisation 3 Origin of Request 4 Test Details 4 Test Conclusions Test Results Markings Fire Evidence

3. Kee Safety Gate Date: 21 st May 2015 Report Reference: 056 - 15 Document No. RS004 Revision 0 3 Issue No. 01 Page 3 of 7 AUTHORISATION Tests performed by: Rob Goodwin (Test Engineer) Report issued by: Rob Goodwin (Test Engineer) Signed: Date: For and on behalf of ASSA ABLOY UK Test Laboratory Report authorised by: Ian Bridge (Test Laboratory Manager) Signed: Date: For and on behalf of ASSA ABLOY UK Test Laboratory Date r eport issued: 21 st May 2015 ASSA AB L OY UK Test Laboratory School Street Willenhall West Midlands WV13 3PW Telephone + 44 (0) 1902 867730 Fax + 44 (0) 1902 867789 This report shall not be reproduced except in full, without written permission from ASSA ABLOY UK Test Laboratory. Test resul ts obtained relate only to the items tested. This report does not constitute an approval, certification or endorsement of the product tested

1. Date: 21 st May 2015 Report Reference: 056 - 15 Document No. RS003 Revision 0 3 Issue No. 01 Page 1 of 7 Test of: Safety Gate Resistance to repeated opening and closing generally in accordance with BS6375 - 2 Customer : Kee Safety Logistics Phil Higgs – Technical & Supplier Quality Manager