Dokumentation
Ose_directory e-shot
2651 Visninger •Checkline II maintenance manual
3019 Visninger •Chemsplash Pro WD40 Test
2377 Visninger •Ergonomi 2006
2922 Visninger •Ose_directory Suspension harness
2688 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3386 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3156 Visninger •VISOR Installation steps
3946 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2938 Visninger •Hearing protection 3M
2490 Visninger •Statistik for arbejdsmiljø 2014
2947 Visninger •LOTO_GuideBook_Europe_English
2496 Visninger •Remote area lighting system
2260 Visninger •Isol8 - The Ultimate Absorbent for Spills
2274 Visninger •Magazine Arbejdsmiljø - november 2012
2438 Visninger •KEE_DOME_MINI
2347 Visninger •TDS Speedglas 9100
2530 Visninger •The Pocketbook of Lean Visuals
2525 Visninger •Instructional video Sign holder
1822 Visninger •PREMARK installation manual
2488 Visninger •D-S CSR Håndbog
16821 Visninger •Find handskestørrelse - størrelsesguide for handsker
9885 Visninger •3M jupiter manual
6045 Visninger •9100 Manual
4929 Visninger •EN 388 nye mærkninger forklaring
4682 Visninger •D-S 70 års om os brochure
4645 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4580 Visninger •Faldsikring flyer
4127 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
3974 Visninger •VISOR Installation steps
3946 Visninger •Guide til valg af åndedrætsværn
3492 Visninger •TR-300 Bruger manual
3476 Visninger •VARMEX 2000 Fordele
3434 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3386 Visninger •3M TR 300 PAPR training video
3336 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3156 Visninger •Procedure for iklædning af engangsbeklædning
3133 Visninger •3020 Solcreme SPF 30 datablad
3116 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3106 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3068 Visninger •APM-145-Product-Manual-Issue-4
Visninger | |
---|---|
334 | Totale visninger |
0 | Medlemmer visninger |
334 | Offentlige visninger |
Del via email
Venligst login for at dele dette presentation via email.
Indlejr på din hjemmeside
1. APM 14 5 PRESSURE METER OPERATING INSTRUCTIONS Crowcon Detection Instruments 172 Brook Drive, Milton Park , Abingdon , Oxfordshire OX14 4SD Tel: 01235 557780 e mail: sales@crowcon.com web: www.anton bycrowcon .com INSTRUMENT OPERATION ON / OFF Press and hold button for 0.5s to turn on. Press and hold button for 2s to turn off. Default switch - off interval is 5 minutes, unless any button is activated or the pressure level is above 1 mbar. MENU STRUCTURE Main Menu Test Menu Let - by / Tightness Pressure Diff Pressure Working Pressure Operating Pressure Flue Draught Pressure Units of Measurement Settings Auto off timeout Back light Key click Report Supervisor settings Set date & time Edit owner line 1 Edit owner line 2 Change Password Stored Logs Select a log Find a log by number Delete all logs Test Menu – Let - by / Tightness U sed to perform let - by, stabilisation and tightness test. Durations, pass & fail controlled by user. Data can be stored & shared. Test Menu – Pressure Used for quick timed pressure tests that do not need to be stored & shared. 1. Positive pressure input spigot 2. Negative pressure input spigot 3. Backlit LCD screen 4. Multi - function 1 button 5. M ulti - function 2 button 6. Multi - function 3 button 7. Power / Enter button 8. Escape / Cancel button 9. Infra - red LED 10. Magnet 11. Tilt stand / hook STANDARD ACCESSORIES The APM 145 is supplied complete with: • Three AA Alkaline batteries • Operating instructions • Protective rubber boot with stand, hook and magnet INSTRUMENT APPLICATION This instrument is not suitable for use with corrosive substances or cyclic hydrocarbons, e.g. motor oil, transmission fluid and Freon. To use the APM 145 with these components, isolation must be provided in the form of a buffer, such as a mineral oil or d ry air.
2. Test Menu – Diff Pressure Used for differential pressure measurement where both pressure spigots are used and the pressure difference is shown on screen. Test Menu – Working Pressure Used to det ermine correct working pressure is set up for appliances. Data can be stored & shared. Test Menu – Operating Pressure Used to determine correct operating pressure is set up for appliances. Data can be stored & shared. Test Menu – Flue Draught Pressure Used to determine correct flue draught pressure. Data can be stored & shared. Units of Measurement Select this menu option to change the pressure units displayed on the meter. Settings Menu – Auto off timeout Changes the period when the unit will switch off if unattended. Settings Menu – Backlight Changes the brightness of t he backlight. Lower settings will prolong battery life. Settings Menu – Key Click Enable/disable button click. Settings Menu – Report Change report sending option (printer, wireless or toggle). Settings Menu – Supervisor Settings User configurable settings. Allows setting of time and date, owner/company name and user password. Stored Logs Menu Search and retrieve stored logs. Allows log to be reviewed, re - printed or re - transmitted over the wireless link. BATTERY REPLACEMENT 1. Remove the protective rubber boot by slipping it away from the bottom of the case and sliding it over the pressure spigots exposing the case back. 2. Remove the battery cover from the bottom of the case by removing the four screws. 3. Remove the three AA batteries and replace with good quality AA Alkaline batteries taking care to install them the right way round. 4. Replace the battery cover carefully making sure it is alligned properly and replace the screw s . Take care not to over tighten the screws otherwis e it may damage the case. For best results and longer life always use quality alkaline batteries MN1500 or equivalent. CAUTIONS Exposure to silicone based products, corrosive gases, water / condensation and freezing should be avoided at all times as this w ill cause damage to the sensor and internal component corrosion. This instrument should not be stored or operated outside of its operating temperature range. Particular care must be taken not to exceed the maximum pressure ratings for the device as this may rupture the sensor membrane. This is not covered by the manufacturer’s warranty. NOTE: The differential/gauge instruments will only measure positive pressures i.e. positiv e pressure applied to positive port, or negative pressure applied to the negative port. WARRANTY This instrument is guaranteed against defects of workmanship and materials for a period of twelve months from date of invoice . During the warranty period a defective instrument will be repaired or replaced at the discretion of the manufacturer. This warranty does not cover damage or failure due to misuse or accident. Modification, adjustment or any alteration shall void the warran ty. For any warranty claims to be considered the instrument must be returned to Anton along with proof of purchase at the sender’s cost. FCC Compliance NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequenc y energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. SPECIFICATIONS Power Supply 3 x AA Alkaline Batteries Battery Life > 2 0 hours* Duty Cycle Continuous. Auto switch off after 5 mins. Operating Temperature - 10 to +50 °C Weight 395 grams including batteries Dimensions 185 x 75 x 43 mm Accuracy ±2% of reading * Using recommended Industrial batteries Units APM 14 5 mbar - 39.99 to +19.99 +20.0 to +130.0 PSI - 0.29 to +1.89 mmHg - 15.00 to +19.99 +20.0 to +98.1 mmH 2 O - 199.9 to +199.9 +200 to +1336 inH 2 O - 8.03 to +52.63 hPa - 39.99 to +19.99 +20.0 to +130.0 Pa - 400 to 9999 kPa - 1.99 to 13.00
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.