6.         Honeywell Internal   RESPIRATORY PROTECTION TECHNICAL DATA SHEET Limited Warranty HONEYWELL INDUSTRIAL SAFETY warrants the Honeywell North Primair 700 Series PAPR to the original owner to be free from defects in materials and workmanship for a per iod of one (1) year from t he date of original shipment from Honeywell’s factory. Honeywell’s obligation under this warranty will be, at Honeywell’s option, to repair or replace without charge the Honeywell North Primair 700 Se ries PAPR or any of its components found by Honeywell to have been defective during the warranty period, under the following terms: 1) The warranty claim is made (i) by the owner who purchased the Honeywell North Primair Series 700 PAPR new from Honeywell or an authorized Honeywell Distributor, and (ii) not more than three (3) months after the end of the warranty period. 2) The Honeywell North Primair 700 Series PAPR or compon ent is found by Honeywell to have been defective in normal use and service during the warranty period of on e (1) year from the date of purchase by the owner. 3) The Honeywell North Primair 700 Series PAPR or component is returned freight prepaid to Honeywell, either to its factory or to a Honeywell authorized service center and is thereafter returned to the owner freight collect. 4) This warranty does not apply (i) to any Honeywell North Primair 700 Series PAPR or component found by Honeywell to have become defective as a result of an y accident, alteration, misuse, abuse, or servicing with parts not approved by Honeywell; (ii) to deterioratio n or aging of any component made of rubber or other elastomer since such components can be adversely affect ed by undue exposure to heat, sun, water, chemicals, ozone or other deteriorating elements; or (iii) facepiece lens, compressed- air cylinders and parts that become defective through normal use. The decision as to wh at constitutes normal use shall be made solely by HONEYWELL INDUSTRIAL SAFETY. 5) To maintain this warranty, the purchaser must perform maintenance and inspections as prescribed in the User’s Instructions which shall include prompt replacement or re pair of defective parts, and r eplacement of parts per the maintenance schedule as prescribed in the User’s Instructions. THE OWNER ASSUMES ALL OTHER RISKS, IF ANY, S UCH AS THE RISK OF ANY DIRECT, INDIRECT OR CONSEQUENTIAL LOSS OR DAMAGE ARISING OUT OF THE USE OF, OR INABILITY TO USE, THE PRODUCT. SERVICING HONEYWELL RESPIRATO RS WITH PARTS NOT APPROVED BY HONEYWELL WILL VOID THIS WARRANTY AND NIOSH APPROVAL FOR THE RESPIRATOR. THIS WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED AND MAY NOT BE VARIED OR EXTENDED EXCEPT IN WRITING BY AN AUTHORIZ ED OFFICIAL OF HONEYW ELL INDUSTRIAL SAFETY.

4.         Honeywell Internal   RESPIRATORY PROTECTION TECHNICAL DATA SHEET Technical Specifications COMPONENT AND ATTRIBUTE SPECIFICATION Operating Conditions Temperature +10°F (-12°C) to +118°F (+48°C) (Note: A low-battery alarm will be trigge red if the internal temperature of the battery reaches 48C) Humidity 20 – 90% R.H. (non-condensing) Altitude 0 – 10,000 ft above sea level Ingress Protection IP65 with battery, breathing tube, filter cartridge and cartridge cover installed Explosive Environments The PA700 series is not suitable for potentially explosive environments. Storage Conditions Temperature Daily: -4°F (-20°C) to +95°F (+35°C) Ideal: 40°F (5°C) to 68°F (20°C) Blower Housing Material PC/ABS Weight 1.77lbs (805g) Air-Flow (loose-fit configurations) 7.2CFM (205lpm) Nominal – Default 7.8CFM (220lpm) Nominal – Medium 8.3CFM (235lpm) Nominal – High Air-Flow (tight-fit configurations) 5.5CFM (155lpm) Nominal Alarms Audible, Visual and Vibratory (See user-instructions for details regarding alarm triggers and sequencing) Motor Life >10,000 hours (est.) Noise Level <75 dBA (average measured at the ear) Battery Pack Materials Housing: PC/ABS Latch: Nylon Gasket: Open-cell silicone foam Weight 0.9lbs (410g) Chemistry Lithium-Ion Capacity 10.9V, 6700mAh, 73wH Run-time ≥ 8hr (average)* Safety Short circuit/Overload/Over voltag e/Over temperature protection Service Life Minimum 500 charge/discharge cycles while maintaining at least 70-80% of the original capacity* Shipping UN38.3 certified for air-transportation (Always consult a logistics professional for information regarding proper shipment of li-ion battery packs)      

2.         Honeywell Internal   RESPIRATORY PROTECTION TECHNICAL DATA SHEET Major Components Blower The PA710 blower is the heart of the PAPR. It draws contaminated ai r through the filt er cartridge and pushes a continuous flow of clean air to the user. Every system is programmed and calibrated at the factory to provide a steady and measured flow of air, even as the filter cartridge becomes saturated with contaminants. The blower also includes an intelligent alarm system that alerts the user when the battery charge or air- flow level is low. The system uses audible, visual and vibratory notifications to effectively and clearly communicate alarm status, even in loud, harsh conditions. Battery and Charger The PA710 blower is powered by a rechargeable lithi um-ion battery pack. The PA720 battery pack can power the PAPR system for an entire 8-hour work shift*. It slides a nd locks into the blower unit, greatly reducing the risk that it will fall and break. The PA720 battery pack also feat ures an on-board, state-of- charge display, which allows the user to evaluate the amount of remaining charge in the pack, without installing it into the blower. The PA724 smart-charger system can re-charge a full y depleted battery in approximately 4.5 hours. In addition to charging, it continuously monitors the heal th of the battery pack and can alert the user to a potential problem via an LED display panel. *Typical expectations based on laboratory test ing. Actual battery run time and batte ry service life is dependent on many facto rs including working environment, charging conditions, filter cartridge type and headpiece type. Belt Assembly The PA700 series belt assemblies have been designed with all-day comfort in mind. The ergonomic shape and choice of materials help distribute the weight of the PAPR evenly on the worker’s body and keep it from slipping. The optional comfort pad can be snapped on, providing even more cushioning support. Breathing Tubes The all-new PA031 and PA031L breathing tubes work exclusively with the new PA700 series PAPR system. They feature simple, twist and lock connector s, a light-weight and highly flexible hose material and a swiveling connection to prevent the hose from twisting or binding. Cartridges & Filters The PA700 Series PAPR is approved for use with th e PA7HE HEPA filter cartridge. The cartridge securely installs into the blower with a simple ¼- turn twist and lock system. It is 99.97% efficient and exceeds NIOSH requirements for service life.

5.         Honeywell Internal   RESPIRATORY PROTECTION TECHNICAL DATA SHEET Battery Charger Time to full charge <4.5 hours in ideal charging conditions (See user-instructions for further details) Display Real-time battery charge and health monitoring (See user-instructions for further details) Power Input Requirements Power Supply: AC 100-240V, 1.5A 50-60Hz Single-bay Charger: DC 19.0V, 2.37A Breathing Tubes Length PA031: 34” PA031L: 40” Materials Connectors: ABS Corrugated Hose: Polyurethane O-Rings: Buna-N, Silicone Belt and Comfort Pad Materials Straps: Woven Nylon Back/Hip Support: Thermoplas tic Polyurethane, PC/ABS Comfort Pad: Closed Cell Polyethylene Foam, Nylon Fabric (TPE Coated) Hardware: Acetal Adjustment Range 28 – 60” (71-152cm) circumference Filter Cartridge Shell Material Polystyrene Particulate Filter Media Hydrophobic, high efficiency particulate media ≥ 99.97% efficient *Typical expectations based on laboratory test ing. Actual battery run time and batte ry service life is dependent on many facto rs including working environment, charging conditions, filter cartridge type and headpiece type. Additional Ordering Information SKU DESCRIPTION QTY/ CASE LENGTH IN (CM) WIDTH IN (CM) HEIGHT IN (CM) WEIGHT LB (KG) PA700 PAPR Assemblies PA701HE PAPR Starter Kit w HEPA 1 - - - 6.0 (2.7) Breathing Hoses PA031 Breathing Tube, Loose Fit 10 19.0 (48. 2) 9.5 (24.1) 9.5 (24.1) 3.5 (1.6) PA031L Breathing Tube, Loose Fit, Long 10 19.0 ( 48.2) 9.5 (24.1) 9. 5 (24.1) 4.0 (1.8) Filter Cartridges PA7HE HEPA Filter Cartridge (5/Box) 20 11.0 (27.9) 11.0 (27.9) 8. 5 (21.6) 11.0 (5.0) Accessories PA75A1 Comfort Pad - - - - - PA71A1 Cartridge Cover, Sm - - - - - Replacement Components PA710 PA700 Series Blower (blower-only) 5 14. 5 (36.8) 9.5 (24.1) 11.0 (27.9) 12.0 (5.5) PA720 Battery Pack, Standard Capa city 1 6.5 3.0 2.5 1.3 (0.6) PA724 1-bay charger kit, N. America 1 - - - 1.3 (0.6) PA722-3A Power Kit, 1-bay charger, N. America 1 - - - 0.8 (0.4) PA751 Standard belt, woven nylon - - - - - CA132 Air Flow Meter 1 No shipping carton specified for this item Note: Additional packaging information pending.

1.       For more information www.honeywellsafety.com RESPIRATORY PROTECTION TECHNICAL DATA SHEET Honeywell Safety Products USA 900 Douglas Pike Smithfield, RI 02917 Phone: 800.873.5242 www.honeywell.com CANADA 10550 Parkway Boulevard Anjou, Quebec H2W 2R2 Phone: 800.873.5242 Honeywell North ® PA700 Series Powered Air Purifying Respirator (PAPR) The Honeywell North PA700 Series is a belt mount ed PAPR approved by the National Institute of Occupational Safety and Health (NIOSH). It is an all- new, integrated respirat ory system that has been engineered to be easy to assemble, operate and maintain. Protection Type This respirator is ideally suited for applications in which non-powered air purifying respirators are not practical or in which a higher protection factor is required, yet where the atmosphere is not immediately dangerous to life and health (IDLH) and where there is an oxygen content of at least 19.5%. When used together with Honeywell North filter cartridges an d Honeywell North facepieces or head covers, the PA700 Series PAPR provides respirat ory protection against most dust s, fumes, mists, particulate radionuclides and radon progeny attached to dusts, fumes and mists. Certifications The PA700 series PAPR meets the requirements of NIOSH CFR 84 when asse mbled from components listed on the NIOSH approval label included with the product. For detailed information on hood/headgear assemblies, s ee the user manuals for those products. Refer to the NIOSH approval labels provided with the PA700 Series blower assembly and filter cartridges for specific NIOSH approval numbers. Assigned Protection Factors The PA700 Series PAPR is for protection from partic ulates where (i) the conc entration does not exceed the Permissible Exposure Limit (PEL) as determined by the Assigned Protection Factor (APF) of the headpiece, (ii) the concentration is below the contaminant’s Immediatel y Dangerous to Life or Health (IDLH) level, and (iii) there is sufficient oxygen in the work environment according to the OSHA Regulation 29 CFR Section 1910.134 or CSA Standard Z94.4 requirements. See the table below for more information regarding the APF. HEADPIECE SERIES P/N DESCRIPTION SWPF TEST RESULTS* Primair 100 Series PA111 Hood assembly with bib >10,000 fit factor APF = 1000 PA121 Hood assembly, Coated, with bib PA131 Hood assembly with collar PA141 Hood assembly, coated, with collar Primair 200 Series PA201E01 Hood assembly with hard hat PA231E01 Hood assembly with hard hat and flame-resistant covers *All hoods tested with PA700 Series PAPR. Test ing conducted by Honeywell Industrial Safety. Note: Because of the positive pressure created by the flow of air, PAPRs have a higher protection factor. The respirator manufacturer must have evidence that testing of these respirat ors demonstrates performance at a level of protection of 1,000 or greater to receive an Assigned Protection Factor (APF) of 1,000. This level of performance can best be demonstrated by performi ng a Workplace Protection Factor (WPF) or Simu lated Workplace Protection Factor (SWPF) st udy or equivalent testing. If such testin g is absent, helmets/hoods are to be treat ed as loose-fitting facepiece respirator s, and should receive an APF of 25.

3.         Honeywell Internal   RESPIRATORY PROTECTION TECHNICAL DATA SHEET Ordering Information A complete NIOSH approved powered air purifying resp irator includes a blower, battery pack, battery charger, belt, flow meter, breathing tube, filter cartridge and headpiece. To simplify the ordering process, the major compone nts of the PA700 Series PAPR can be purchased as a kit. Unless otherwise noted, breathing tubes, filter ca rtridges, filter cartridge covers and headpieces are sold separately. STEP 1: SELECT YOUR PA700 SERIES PAPR BLOWER ASSEMBLY PA701HE Assembly includes blower, battery, battery charger, comfort pad, and nylon belt and free starter kit (P100 HEPA filter and optio nal filter cover) PA701 Assembly includes blower, battery, battery charger, comfort pad, and nylon belt PA701D* Assembly includes blower, battery, battery charger, comfort pad, and PVC belt STEP 2: SELECT YOUR HOOD OR FACEPIECE PA100 Series Head Covers & Hoods PA200 Series Hoods Half Masks Full Facepieces Welding Full Facepieces PA111 PA201E01 770030S, M, L* 760008A, S* 760008AW, SW* PA121 PA231E01 550030S, M, L* 54001, S* 54001W, SW* PA131 PA141 PA101S, M* STEP 3: SELECT YOUR BREATHING TUBE   PA031 Straight Breathing Tube for Primair Hoods, 34" PA031L Straight Breathing Tube for Primair Hoods, 40" PA034* Y-Shape Breathing Tube for tight fitting facepieces, 34" PA034L* Y-Shape Breathing Tube for tight fitting facepieces, 40" STEP 4: SELECT YOUR CARTRIDGE OR FILTER   PA7HE P100 HEPA** Filter NOTE: Cartridge/Filter Combinations pending NIOSH approval STEP 5: SELECT YOUR ACCESSORIES   PA75A1 Comfort Pad PA71A1 Filter Cover/Shower Cap CA113 Fabric Cover for straight breathing tubes (for use with PA031 and PA031L) CA114* Fabric Cover for Y-shape breathing tubes (for use with PA034* and PA034L*) 7003 Refresher wipes, with alcohol 7003A Refresher wipes, alcohol free 80995 Cleaner/Sanitizer, 10oz bottle (not available in Canada) *Pending NIOSH approval **HEPA (High Efficiency Particulate Air-Purifying), 99.97% minimum filter efficiency for all particulates.