Dokumentation
Ose_directory e-shot
2640 Visninger •Checkline II maintenance manual
3008 Visninger •Chemsplash Pro WD40 Test
2368 Visninger •Ergonomi 2006
2908 Visninger •Ose_directory Suspension harness
2679 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3373 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3147 Visninger •VISOR Installation steps
3933 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2925 Visninger •Hearing protection 3M
2480 Visninger •Statistik for arbejdsmiljø 2014
2931 Visninger •LOTO_GuideBook_Europe_English
2483 Visninger •Remote area lighting system
2252 Visninger •Isol8 - The Ultimate Absorbent for Spills
2265 Visninger •Magazine Arbejdsmiljø - november 2012
2431 Visninger •KEE_DOME_MINI
2332 Visninger •TDS Speedglas 9100
2522 Visninger •The Pocketbook of Lean Visuals
2517 Visninger •Instructional video Sign holder
1810 Visninger •PREMARK installation manual
2471 Visninger •D-S CSR Håndbog
16776 Visninger •Find handskestørrelse - størrelsesguide for handsker
9855 Visninger •3M jupiter manual
6018 Visninger •9100 Manual
4888 Visninger •EN 388 nye mærkninger forklaring
4667 Visninger •D-S 70 års om os brochure
4623 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4566 Visninger •Faldsikring flyer
4085 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
3950 Visninger •VISOR Installation steps
3933 Visninger •Guide til valg af åndedrætsværn
3482 Visninger •TR-300 Bruger manual
3464 Visninger •VARMEX 2000 Fordele
3421 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3373 Visninger •3M TR 300 PAPR training video
3323 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3147 Visninger •Procedure for iklædning af engangsbeklædning
3122 Visninger •3020 Solcreme SPF 30 datablad
3105 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3095 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3059 Visninger •Crowcon I-test-Data-Sheet
Visninger | |
---|---|
269 | Totale visninger |
0 | Medlemmer visninger |
269 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
1. I-Test Automated Portable Gas Detector Test Station Quick Automated Compliance
2. Flexible Mains powered, or battery back-up Allows you to use on site, or in field Entirely self-contained No extra computers or equipment required Ability to update Gas-Pro and T4 configurations Update the bump test interval or alarm levels of your fleet with ease and no fleet downtime Data management Archive gas level data from detectors long term Powerful support software Makes configuring I-Test to site requirements extremely easy Reliable I-Test recognises empty or expired cylinders Allows for planned refills and no unit downtime Testing starts automatically when detector is inserted Minimal user training required Ensures the audible and visual alarms are working Gives the user full confidence that the Gas-Pro is compliant to use Battery backup Testing continues even if power is out Records Everything is logged See everything that has been tested and whether it has passed/failed Exception reporting Precise reports flag up who has and hasn’t carried out their bump test or calibration Powerful reporting Need to see which detectors have gone in to alarm in the last month? I-Test Manager makes easy work of pulling report summaries together Ensuring your site is compliant I-Test is Crowcon’s fully automated solution for testing and verifying that your Gas-Pro and T4 are in a compliant state to carry out your daily work. Bump testing standards are getting tighter in all regions and the need for controlled bump and calibration records is a must. I-Test and the accompanying I-Test manager software makes this easy. It takes less than 1 minute to complete a bump test with I-Test I-Test Automated Bump Test Station
3. I-Test Manager I-Test Manager is Crowcon’s software solution for the control of your data that has been collected through the I-Test. The software platform is intuitive and can be used by multiple users giving you the ability to run the correct reports for your department. With the I-Test Manager you can do the following: Simple to use When the Gas-Pro or T4 are inserted into I-Test, no button presses are required and I-Test starts testing automatically. A bump test takes less than 1 minute. The test carries out verification that the sensors are responding to a known value of gas, and filters are clear and good for use. It will also ensure the audible and visual alarms are working, giving the user full confidence that they are compliant for site use. Manage cylinders View data Field configuration Create reports Inlet configuration Exception reporting • Data reporting in graph form • Search by date • Full site record keeping • Ensure gas is tracked • Ensure gas is in date • Flexibility of concentrations • Site compliant • Tailored reporting • Print or save certificates • Change a fleet easily • Ensure unit is up to latest standards • No down time • Ensure everyone is following site rules • Report on missing units • Flexibility on reports • Flexibility of use • Ensure correct gas is being used
4. www.crowcon.com © 2022 Crowcon Detection Instruments Ltd. Copyright to some photographs held separately. Specification Size 110 x 250 x 320mm (4.3 x 9.8 x 12.6 ins) Weight 2kg (70.5oz) Input Supply 9-12V @ 3A I-Test backup battery 200 speedy bump tests with 15-second intervals between tests 5 hours in standby with no bump test Battery life approximately 500 cycles Charge time 7 hours RTC backup battery 3-year life USB interface One standard USB type A socket for USB Flash Memory stick One standard USB type B socket for connections to PC Inlets/Outlets Single gas inlet (requires demand flow regulator) Purge inlet (air) Exhaust Regulators Demand flow regulator required Storage capacity Internal 2GB MicroSD card Temperature specifications Operating temperature: -10 o C to +50 o C Storage temperature: -25 o C to +60 o C Charging temperature: 0 o C to +40 o C Humidity 0% and 95% relative humidity (non-condensing) at +40 o C Ingress protection IP20 Accessories Demand flow regulator Calibration gas Cylinder holder Crowcon reserves the right to change the design or specification of the product without notice. Disclaimer Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company’s policy of continued product improvement Crowcon Detection Instruments Limited reserves the right to make product changes without notice. The products are routinely subject to a programme of testing which may result in some changes in the characteristics quoted. Technical information contained in this document or otherwise provided by Crowcon are based upon records, tests, or experience that the company believes to be reliable, but the accuracy, completeness, and representative nature of such information is not guaranteed. Many factors beyond Crowcon Detection Instruments’ control and uniquely within user’s knowledge and control can affect the use and performance of a Crowcon product in a particular application. As the products may be used by the client in circumstances beyond the knowledge and control of Crowcon Detection Instruments Limited, we cannot determine the relevance of these to an individual customer’s application. It is the clients’ sole responsibility to carry out the necessary tests to evaluate the usefulness of the products and review all applicable regulations and standards to ensure their safety of operation in a particular application.
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.