Dokumentation
Ose_directory e-shot
2651 Visninger •Checkline II maintenance manual
3019 Visninger •Chemsplash Pro WD40 Test
2377 Visninger •Ergonomi 2006
2921 Visninger •Ose_directory Suspension harness
2688 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3386 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3156 Visninger •VISOR Installation steps
3946 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2938 Visninger •Hearing protection 3M
2490 Visninger •Statistik for arbejdsmiljø 2014
2946 Visninger •LOTO_GuideBook_Europe_English
2496 Visninger •Remote area lighting system
2260 Visninger •Isol8 - The Ultimate Absorbent for Spills
2273 Visninger •Magazine Arbejdsmiljø - november 2012
2438 Visninger •KEE_DOME_MINI
2347 Visninger •TDS Speedglas 9100
2530 Visninger •The Pocketbook of Lean Visuals
2525 Visninger •Instructional video Sign holder
1822 Visninger •PREMARK installation manual
2488 Visninger •D-S CSR Håndbog
16821 Visninger •Find handskestørrelse - størrelsesguide for handsker
9882 Visninger •3M jupiter manual
6043 Visninger •9100 Manual
4927 Visninger •EN 388 nye mærkninger forklaring
4682 Visninger •D-S 70 års om os brochure
4645 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4580 Visninger •Faldsikring flyer
4127 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
3974 Visninger •VISOR Installation steps
3946 Visninger •Guide til valg af åndedrætsværn
3491 Visninger •TR-300 Bruger manual
3476 Visninger •VARMEX 2000 Fordele
3433 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3386 Visninger •3M TR 300 PAPR training video
3336 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3156 Visninger •Procedure for iklædning af engangsbeklædning
3133 Visninger •3020 Solcreme SPF 30 datablad
3116 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3106 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3068 Visninger •Chemical Recommendation Guide AlphaTec 09-430
Visninger | |
---|---|
160 | Totale visninger |
0 | Medlemmer visninger |
160 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
1. Permeation breakthrough times and degradation data according to EN ISO 374:2016 AlphaTec® 09-430 Chemical agent CAS Number Breakthrough Time (min) Protection Index Degradation (%) Part Formaldehyde, 37% 50-00-0 > 480 6 -19.4 Cuff Formaldehyde, 37% 50-00-0 > 480 6 -3.1 Palm Hydrogen Peroxide, 30% 7722-84-1 > 480 6 -14 Cuff Hydrogen Peroxide, 30% 7722-84-1 > 480 6 -15.1 Palm Methanol 67-56-1 388 5 -6.1 Cuff Methanol 67-56-1 > 480 6 5.1 Palm Nitric Acid, 65% 7697-37-2 > 480 6 3 Cuff Nitric Acid, 65% 7697-37-2 > 480 6 -6.9 Palm Sodium Hydroxide, 40% 1310-73-2 > 480 6 -8.1 Cuff Sodium Hydroxide, 40% 1310-73-2 > 480 6 -2.3 Palm Sulfuric Acid, 96% 7664-93-9 146 4 -13.7 Cuff Sulfuric Acid, 96% 7664-93-9 464 5 -14.4 Palm Permeation breakthrough times according to EN ISO 374:2016 0 1 2 3 4 5 6 < 10 10-30 30-60 60-120 120-240 240-480 > 480 Not recommended Splash protection Medium protection High protection Data given in the table above are based on results of laboratory tests performed on the palm or cuff area of the glove. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. We wish to highlight that permeation times do not equate to safe wear time. Safe wear time may vary depending on whether the PPE is donned correctly, the surrounding temperature, the chemicals’ toxicity, and other factors. Permeation information offered here is limited to the main protective material. Permeation times may vary around seams, zips, visors or any other joins or components of the PPE. It is the responsibility of your organization’s Health and Safety professional to undertake a risk assessment before choosing the appropriate PPE for the task at hand. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability. Ansell Healthcare Europe N.V. Riverside Business Park, Block J Boulevard International 55, 1070 Brussels, Belgium Tel. +32 (0) 2 528 74 00 Fax +32 (0) 2 528 74 01 http://www.ansell.eu E-mail info.europe@ansell.com
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.