1. 02 KEY FEATURES • Easy installation • 110-220 V AC supply • Multiple sensors available • Flexible output options • 3 alarm levels • Adjustment by keypad • Addressable or independent • RS485 or RS232 communication by means of adapter • 4-20 mA analogue output • Plug and Play • Calibration by a single person • Two alarm relays plus fault relay • Datalogging • NFC™ Power Supply 110-220 VAC Outputs 4-20mA (3 wires) and ModBus RS485 (4 wires) Low alarm relay 2A @ 250 V High alarm relay 2A @ 250 V Relays inhibition during adjustment Display LCD 4 digits Indicators Working: Green LED Alarm: Red LED and status warning on display Fault: Orange LED and status warning on display Datalogging 8192 events (5 days in continuos) Data Download NFC with free App SmartSens (Android) Protection IP-65 Cable Entry 3 x PG9 Weight 1,5 Kg Dimensions 15,8 cm x 15 cm x 8,5 cm Temperature -10 ºC to + 50 ºC Humidity 0 to 99% RH (non-condensation) 03 TECHNICAL SPECIFICATIONS The Sensotox C2 can use a wide range of sensor types for a variety of configurations, allowing the gas reading to be shown on its display and alarm and signalling relays to be activated. Available sensors include electrochemical ones for oxygen and toxic gases, catalytic and infrared ones for flammable gases, infrared ones for CO 2 and PID for Volatile Organic Compounds. It also has a 4-20 mA analogue output for connection to external systems as well as a ModBus digital output to enable connection of multiple control panels on a single loop. The status LEDs also indicate correct operation, if any of the alarm relays is activated. The Sensotox C2 comes ready to be easily installed, needing only a 110-220 VAC or a 12-24 VDC supply. The network of sensors in ModBus may be connected to a GasVisor panel which will monitor the status of each detector to indicate alarm and sensor status conditi ons, with a wide variety of controls, indications and options. It also allows the connection of up to 8 Sensotox C2 units to a GasVisor panel via a 4-20 mA analogue output. Additionally, it has a data storage system with capacity for of 8000 events, to log any alarm event. It can also store up to 5 days of readings at one-minute intervals. This data will be downloaded directly to a PC via RS485, however the last 5 events will be downloaded to a phone with NFC™ technology using the SmartSens application. 01 PRODUCT DESCRIPTION Sensotox C2 Remote Gas Detector Panel with Display and relays fitted with NFC™

2. 04 CONNECTION SCHEME 05 ORDERING INFORMATION* Reference Gas Range Sensor C2–001–XY O 2 0 – 30% vol. Electrochemical C2–002–XY CO 0 – 1.000 ppm Electrochemical C2–003–XY H 2 S 0–100 ppm Electrochemical C2–004–XY NO 0–250 ppm Electrochemical C2–005–XY NO 2 0–20 ppm Electrochemical C2–006–XY CI 2 0 – 10 ppm Electrochemical C2–007–XY SO 2 0 – 20 ppm Electrochemical C2–008–XY NH 3 (standard range) 0 – 300 ppm Electrochemical C2–009–XY NH 3 (high range) 0 – 1.000 ppm Electrochemical C2–010–XY CH 4 Vol. (IR high range) 0 – 100% vol. Infrared C2–011–XY CO 2 0 – 10.000 ppm Infrared C2–012–XY CO 2 0 – 50.000 ppm Infrared C2–013–XY CO 2 0 – 100% vol. Infrared C2–014–XY COV 0,01 – 20,0 ppm PID C2–015–XY COV 0,1 – 200 ppm PID C2–016–XY COV 0 – 2.000 ppm PID C2–017–XY PH 3 0 – 20 ppm Electrochemical C2–018–XY H 2 S (high range) 0 – 2.000 ppm Electrochemical C2–019–XY L.E.L. (IR) 0 – 100% L.E.L. Infrared C2–021–XY ETO 0 – 10 ppm Electrochemical C2–022–XY HCN 0 – 50 ppm Electrochemical C2–023–XY HF 0 – 10 ppm Electrochemical C2–024–XY H 2 0 – 2.000 ppm Electrochemical C2–025–XY O 3 0 – 10 ppm Electrochemical C2–026–XY HCl 0 – 50 ppm Electrochemical C2–027–XY HCHO 0 – 10 ppm Electrochemical C2–028–XY CH 3 SH 0 – 10 ppm Electrochemical C2–029–XY C 2 H 3 Cl 0 – 20 ppm Electrochemical C2–030–XY ClO 2 0 – 10 ppm Electrochemical Sensotox C2 GasVisor 4 – 20 mA ModBus RS 485 Detector 32 Detector 3 Detector 2 Detector 1 Bus 4 Bus 3 Bus 2 Bus 1 Av. Remolar, 31 08820 El Prat de Llobregat Barcelona (Spain) T. (+34) 934 785 842 sensotran@sensotran.com www.sensotran.com

app-image

To install this Web App in your iPhone/iPad press pwa-icon and then Add to Home Screen.

Sikkerhed for alle

Hold dig sikkert opdateret med seneste nyheder og viden indenfor PPE og arbejdsmiljø