Dokumentation
Ose_directory e-shot
2672 Visninger •Checkline II maintenance manual
3041 Visninger •Chemsplash Pro WD40 Test
2401 Visninger •Ergonomi 2006
2952 Visninger •Ose_directory Suspension harness
2713 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3414 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3176 Visninger •VISOR Installation steps
3966 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2958 Visninger •Hearing protection 3M
2511 Visninger •Statistik for arbejdsmiljø 2014
2966 Visninger •LOTO_GuideBook_Europe_English
2520 Visninger •Remote area lighting system
2282 Visninger •Isol8 - The Ultimate Absorbent for Spills
2297 Visninger •Magazine Arbejdsmiljø - november 2012
2464 Visninger •KEE_DOME_MINI
2369 Visninger •TDS Speedglas 9100
2552 Visninger •The Pocketbook of Lean Visuals
2551 Visninger •Instructional video Sign holder
1840 Visninger •PREMARK installation manual
2511 Visninger •D-S CSR Håndbog
16907 Visninger •Find handskestørrelse - størrelsesguide for handsker
9943 Visninger •3M jupiter manual
6078 Visninger •9100 Manual
4994 Visninger •EN 388 nye mærkninger forklaring
4702 Visninger •D-S 70 års om os brochure
4672 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4609 Visninger •Faldsikring flyer
4200 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
3997 Visninger •VISOR Installation steps
3966 Visninger •Guide til valg af åndedrætsværn
3522 Visninger •TR-300 Bruger manual
3496 Visninger •VARMEX 2000 Fordele
3468 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3414 Visninger •3M TR 300 PAPR training video
3370 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3176 Visninger •Procedure for iklædning af engangsbeklædning
3153 Visninger •3020 Solcreme SPF 30 datablad
3133 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3124 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3086 Visninger •T4x-Datasheet-British-English
Visninger | |
---|---|
124 | Totale visninger |
0 | Medlemmer visninger |
124 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
3. Gases and ranges Gas Range Resolution Oxygen (O 2 ) 0-30% vol. 0.1% vol. Oxygen (O 2 ) Long Life 0-25% vol 0.1% vol Flammable 0-100% LEL 1% LEL Hydrogen sulphide (H 2 S) 0-100ppm 1ppm Carbon monoxide (CO) 0-1000ppm 1ppm Product variants and options Gas Sensor Options Configurations 2 gas 3 gas 4 gas New New Oxygen (O 2 ) Oxygen (O 2 ) Long Life Flammable MPS TM Flammable Pellistor Hydrogen sulphide (H 2 S) Carbon monoxide (CO) Carbon monoxide (CO) - H 2 immune
2. T4x Features TWA resume function Unique this innovative feature ensures toxic gas exposure is calculated accurately over an entire shift, even if switched off for a break or during travel to another site. Battery life T4x: 35+ hours battery (double the battery life of our original T4) allows multiple or longer shifts to be worked between recharging. Backlit display Large, clear display with backlight and option to flip the screen 180° for easy viewing whilst worn. Rugged design With a thick anti-shock rubber casing and drop tested to 4 metres on concrete, provides dependable operation under the most demanding use. Water & dust resistant to IP65 & IP67 Provides protection in the harshest environments. Dedicated sensors One sensor for every gas ensures effective, fast and reliable detection. Positive safety indicator A simple ‘traffic light’ status indicator which, at a glance, provides visual assurance of operational and compliance status to both users and supervisors. Green light - Working safely Red light - Attention required Intrinsically safe T4x: ATEX Type 1 (Zone 0) approved and UL Class 1 Division 1 allows for uninterrupted working in the most demanding environments. Multiple alarms Audible 95dB alarm, bright red/blue LED’s and vibrating alerts provide effective warning to gas hazards. Easy operation Large single button and intuitive menu system minimise training and allow easy operation whilst wearing gloves. T4x helps ensure compliance across site by eliminating the need to ensure each device is calibrated for the relevant flammable gas as it accurately detects more than 15 flammable gases, in any mix, at once, while being Type 1. Being poison resistant and with battery life doubled, operators are more likely to never be without a device. T4x reduces the 5 year total cost of ownership by over 25% and saves 12g of lead per detector which makes it easier to recycle at the end of its life, and better for the planet.
1. Specification Size 135 x 80 x 35mm (5.3 x 3.1 x 1.4in) Weight 282g (9.9oz) Durability Drop tested 4m onto concrete Alarms Audible Vibrating Visible 95dB Integrated Bright red & blue LED’s Display Front mounted, backlit, 180° flip for easy viewing while worn Logging Data Events 130 hours of data at 10s intervals 3,500 Battery Rechargeable Li-ion Up to 35 hours run time with MPS TM sensor fitted; 5.5 hour recharge Environment Operating temp Humidity Ingress protection -20 to +55°C (-4°F to +131°F)* 10-95% RH @ 40°C non-condensing Independently tested to IP65 and IP67 Compliance EMC Directive 2014/30/EU Approvals T4x ATEX and UKCA: II 1 G Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1) IECEx : Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1) UL USA and cUL: Use in hazardous locations Class 1 Div 1 groups A,B,C,D only as to intrinsic safety MED: Directive 2014/90/EU Accessories Included with Integrated alligator clip and tethering loop Bump/calibration plate Available separately Single unit cradle charger; 10 unit cradle charger; Vehicle charger Clip on dust filter plate I-Test automated bump test and calibration station Crowcon Connect Compatible? Ye s *Toxic and oxygen sensors are not rated for continuous operation above 50°C (122°F) T4x Personal 4 Gas Monitor Now with industry leading MPS TM flammable gas and Long-Life oxygen sensors.
4. www.crowcon.com Specification Size 135 x 80 x 35mm (5.3 x 3.1 x 1.4in) Weight 282g (9.9oz) Durability Drop tested 4m onto concrete Alarms Audible Vibrating Visible 95dB Integrated Bright red & blue LED’s Display Front mounted, backlit, 180° flip for easy viewing while worn Logging Data Events 130 hours of data at 10s intervals 3,500 Battery Rechargeable Li-ion Up to 35 hours run time with MPS TM sensor fitted; 5.5 hour recharge Environment Operating temp Humidity Ingress protection -20 to +55°C (-4°F to +131°F)* 10-95% RH @ 40°C non-condensing Independently tested to IP65 and IP67 Compliance EMC Directive 2014/30/EU Approvals T4x ATEX and UKCA: II 1 G Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1) IECEx : Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1) UL USA and cUL: Use in hazardous locations Class 1 Div 1 groups A,B,C,D only as to intrinsic safety MED: Directive 2014/90/EU Accessories Included with Integrated alligator clip and tethering loop Bump/calibration plate Available separately Single unit cradle charger; 10 unit cradle charger; Vehicle charger Clip on dust filter plate I-Test automated bump test and calibration station Crowcon Connect Compatible? Ye s *Toxic and oxygen sensors are not rated for continuous operation above 50°C (122°F) © 2022 Crowcon Detection Instruments Ltd. Copyright to some photographs held separately. Crowcon reserves the right to change the design or specification of the product without notice. Disclaimer Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company’s policy of continued product improvement Crowcon Detection Instruments Limited reserves the right to make product changes without notice. The products are routinely subject to a programme of testing which may result in some changes in the characteristics quoted. Technical information contained in this document or otherwise provided by Crowcon are based upon records, tests, or experience that the company believes to be reliable, but the accuracy, completeness, and representative nature of such information is not guaranteed. Many factors beyond Crowcon Detection Instruments’ control and uniquely within user’s knowledge and control can affect the use and performance of a Crowcon product in a particular application. As the products may be used by the client in circumstances beyond the knowledge and control of Crowcon Detection Instruments Limited, we cannot determine the relevance of these to an individual customer’s application. It is the clients’ sole responsibility to carry out the necessary tests to evaluate the usefulness of the products and review all applicable regulations and standards to ensure their safety of operation in a particular application.
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.