Dokumentation
Ose_directory e-shot
2677 Visninger •Checkline II maintenance manual
3044 Visninger •Chemsplash Pro WD40 Test
2405 Visninger •Ergonomi 2006
2958 Visninger •Ose_directory Suspension harness
2719 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3421 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3183 Visninger •VISOR Installation steps
3972 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2961 Visninger •Hearing protection 3M
2515 Visninger •Statistik for arbejdsmiljø 2014
2970 Visninger •LOTO_GuideBook_Europe_English
2522 Visninger •Remote area lighting system
2282 Visninger •Isol8 - The Ultimate Absorbent for Spills
2298 Visninger •Magazine Arbejdsmiljø - november 2012
2466 Visninger •KEE_DOME_MINI
2378 Visninger •TDS Speedglas 9100
2555 Visninger •The Pocketbook of Lean Visuals
2557 Visninger •Instructional video Sign holder
1844 Visninger •PREMARK installation manual
2515 Visninger •D-S CSR Håndbog
16956 Visninger •Find handskestørrelse - størrelsesguide for handsker
9968 Visninger •3M jupiter manual
6095 Visninger •9100 Manual
5029 Visninger •EN 388 nye mærkninger forklaring
4709 Visninger •D-S 70 års om os brochure
4685 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4624 Visninger •Faldsikring flyer
4229 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
4007 Visninger •VISOR Installation steps
3972 Visninger •Guide til valg af åndedrætsværn
3536 Visninger •TR-300 Bruger manual
3511 Visninger •VARMEX 2000 Fordele
3479 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3421 Visninger •3M TR 300 PAPR training video
3383 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3183 Visninger •Procedure for iklædning af engangsbeklædning
3157 Visninger •3020 Solcreme SPF 30 datablad
3136 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3128 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3090 Visninger •PAF-0060-CleanSpace-EX-Intrinsically-Safe-Approvals-Explained
Visninger | |
---|---|
45 | Totale visninger |
0 | Medlemmer visninger |
45 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
2. IECE x APPROVALS (INTERNATIONAL INTRINSICALLY SAFE REQUIREMENTS) Ex ia I Ma Ex – Explosion Proof Certification ia – Ignition Protection Level: Intrinsic Safety, Very High level of protection. Suitable for use in Zones 0, 1, & 2. I – Gas Subdivision Group: Represented by Methane Gas. Ma – Equipment Protection Level: Very High Level of Protection against methane & coal dust in underground mines. Ex ib IIB T4 Gb Ex – Explosion Proof Certification ib – Ignition Protection Level: Intrinsic Safety, High level of protection. Suitable for use in Zones 1 & 2. IIB – Gas Subdivision Group: Represented by Ethylene. Includes less ignitable groups IIA (Propane) and I (Methane). T4 – Temperature Class: Max Surface Temperature of 135 ̊C. Gb – Equipment Protection Level: High, Suitable for use in Zones 1 & 2 in aboveground explosive environments. Reference Standard Description IECEx Standards IEC 60079-0:2017 General Requirements IECEx Standards IEC 60079-11:2011 Equipment Protection by Intrinsic Safety (i) IECEx Quality Assurance IEC 80079-34:2018 Application of Quality Management Systems for Ex Product Manufacture Cleanspace Technology Pty Ltd ABN 24 146 453 554 T: +61 2 8436 4000 U5, 39 Herbert Street St. Leonards NSW 2065 Australia sales@cleanspacetechnology.com www.cleanspacetechnology.com NE002530 SUMMARY: Suitable for use in underground mining applications Zones 0, 1 & 2 with presence of methane gas & coal dust that requires a very high level of equipment protection and very high level of ignition protection. SUMMARY: Suitable for use in above ground applications Zones 1 & 2 with gases up to Ethylene that require a high level of equipment protection and a high level of ignition protection against gas, vapor and mist. Not suitable for use in Zone 0. This information is a guide only and is not intended to be comprehensive. We recommend a safety manager or qualified technical engineer is consulted. ATEX/IECEx Definitions Equipment Group (ATEX Only) I Underground mining operations Equipment Protection Level Ma Very High against Methane & Coal Dust II Operations other than underground mines Mb High against Methane & Coal Dust Ga Very High against Gas, Mist & Vapor Equipment Category M1 Two Faults Gb High against Gas, Mist & Vapor M2 Severe Normal Operation Gc Normal against Gas, Mist & Vapor 1 Two Faults 2 One Fault Area Classification Category 1 Zone 0 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. 3 Normal Operation Explosive Atmosphere G Gas, Vapor, Mist D Dust Explosion Protection (Ex) ia Intrinsic Safety - Very High Ignition Protection Category 2 Zone 1 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally. ib Intrinsic Safety - High Ignition Protection Gas Subgroup I Methane-Least easily ignited IIA Propane-Less easily ignited IIB Ethylene-More easily ignited Category 3 Zone 2 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. IIC Hydrogen/Acetylene-Most easily ignited Temperature Class (Max Surface Temp) T3 200 ̊C T4 135 ̊C T5 100 ̊C
1. CLEANSPACE EX PAPR INTRINSIC APPROVALS PAF-0060 ATEX APPROVALS (REQUIRED FOR EU COUNTRIES) I M1 Ex ia I Ma I – Equipment Group: Suitable for use in underground mines. M1 – Equipment Category: Mines involving methane gas. Ex ia – Ignition Protection Level: Intrinsic Safety, Very High level of protection. Suitable for use in Zones 0, 1, & 2. I – Gas Subdivision Group: Represented by Methane Gas. Ma – Equipment Protection Level: Very High Level of Protection against methane & coal dust in underground mines. II 2 G Ex ib IIB T4 Gb II – Equipment Group: Suitable for use in aboveground explosive atmospheres. 2G – Equipment Category: Aboveground explosive environments involving Gas, Vapor, Mist. Ex ib – Ignition Protection Level: Intrinsic Safety, High level of protection. Suitable for use in Zones 1 & 2. IIB – Gas Subdivision Group: Represented by Ethylene. Includes less ignitable groups IIA (Propane) and I (Methane). T4 – Temperature Class: Max Surface Temperature of 135 ̊C. Gb – Equipment Protection Level: High, Suitable for use in Zones 1 & 2 in aboveground explosive environments. Reference Standard Description ATEX / EN EX Standards EN 60079-0:2018 General Requirements ATEX / EN EX Standards EN 60079-11:2012 Equipment Protection by Intrinsic Safety (i) ATEX Quality Assurance Annex IV, Directive 2014/34/EU Conformity to Type Based on Quality Assurance of the Production Process ATEX/IECEx Definitions Equipment Group (ATEX Only) I Underground mining operations Equipment Protection Level Ma Very High against Methane & Coal Dust II Operations other than underground mines Mb High against Methane & Coal Dust Ga Very High against Gas, Mist & Vapor Equipment Category M1 Two Faults Gb High against Gas, Mist & Vapor M2 Severe Normal Operation Gc Normal against Gas, Mist & Vapor 1 Two Faults 2 One Fault Area Classification Category 1 Zone 0 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. 3 Normal Operation Explosive Atmosphere G Gas, Vapor, Mist D Dust Explosion Protection (Ex) ia Intrinsic Safety - Very High Ignition Protection Category 2 Zone 1 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally. ib Intrinsic Safety - High Ignition Protection Gas Subgroup I Methane-Least easily ignited IIA Propane-Less easily ignited IIB Ethylene-More easily ignited Category 3 Zone 2 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. IIC Hydrogen/Acetylene-Most easily ignited Temperature Class (Max Surface Temp) T3 200 ̊C T4 135 ̊C T5 100 ̊C SUMMARY: Suitable for use in underground mining applications Zones 0, 1 & 2 with presence of methane gas & coal dust that requires a very high level of equipment protection and very high level of ignition protection. SUMMARY: Suitable for use in aboveground applications Zones 1 & 2 with gases up to Ethylene that require a high level of equipment protection and a high level of ignition protection against gas, vapor and mist. Not suitable for use in Zone 0. WWW.CLEANSPACETECHNOLOGY.COM sales@cleanspacetechnology.com
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.