Dokumentation
Ose_directory e-shot
2666 Visninger •Checkline II maintenance manual
3033 Visninger •Chemsplash Pro WD40 Test
2392 Visninger •Ergonomi 2006
2942 Visninger •Ose_directory Suspension harness
2703 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3404 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3170 Visninger •VISOR Installation steps
3962 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2953 Visninger •Hearing protection 3M
2505 Visninger •Statistik for arbejdsmiljø 2014
2959 Visninger •LOTO_GuideBook_Europe_English
2511 Visninger •Remote area lighting system
2273 Visninger •Isol8 - The Ultimate Absorbent for Spills
2290 Visninger •Magazine Arbejdsmiljø - november 2012
2455 Visninger •KEE_DOME_MINI
2362 Visninger •TDS Speedglas 9100
2543 Visninger •The Pocketbook of Lean Visuals
2541 Visninger •Instructional video Sign holder
1837 Visninger •PREMARK installation manual
2504 Visninger •D-S CSR Håndbog
16881 Visninger •Find handskestørrelse - størrelsesguide for handsker
9923 Visninger •3M jupiter manual
6065 Visninger •9100 Manual
4975 Visninger •EN 388 nye mærkninger forklaring
4697 Visninger •D-S 70 års om os brochure
4668 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4600 Visninger •Faldsikring flyer
4185 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
3990 Visninger •VISOR Installation steps
3962 Visninger •Guide til valg af åndedrætsværn
3513 Visninger •TR-300 Bruger manual
3490 Visninger •VARMEX 2000 Fordele
3456 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3404 Visninger •3M TR 300 PAPR training video
3362 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3170 Visninger •Procedure for iklædning af engangsbeklædning
3145 Visninger •3020 Solcreme SPF 30 datablad
3128 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3116 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3082 Visninger •Chemical Recommendation Guide TouchNTuff 93-300
Visninger | |
---|---|
231 | Totale visninger |
0 | Medlemmer visninger |
231 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
1. Permeation breakthrough times and degradation data according to EN ISO 374:2016 TouchNTuff® 93-300 Chemical agent CAS Number Breakthrough Time (min) Protection Index Degradation (%) Part Formaldehyde, 37% 50-00-0 > 480 6 0.9 Palm Heptane 142-82-5 > 480 6 2.8 Palm Hydrogen Peroxide, 30% 7722-84-1 33 2 34.3 Palm Sodium Hydroxide, 40% 1310-73-2 > 480 6 -41.6 Palm Permeation breakthrough times according to EN ISO 374:2016 0 1 2 3 4 5 6 < 10 10-30 30-60 60-120 120-240 240-480 > 480 Not recommended Splash protection Medium protection High protection Data given in the table above are based on results of laboratory tests performed on the palm or cuff area of the glove. These tests were run using standard test methods that may not adequately replicate any specific conditions of end use. We wish to highlight that permeation times do not equate to safe wear time. Safe wear time may vary depending on whether the PPE is donned correctly, the surrounding temperature, the chemicals’ toxicity, and other factors. Permeation information offered here is limited to the main protective material. Permeation times may vary around seams, zips, visors or any other joins or components of the PPE. It is the responsibility of your organization’s Health and Safety professional to undertake a risk assessment before choosing the appropriate PPE for the task at hand. Because Ansell has no detailed knowledge or control over the conditions of end use, any of these data must be advisory only, and Ansell must decline any liability. Ansell Healthcare Europe N.V. Riverside Business Park, Block J Boulevard International 55, 1070 Brussels, Belgium Tel. +32 (0) 2 528 74 00 Fax +32 (0) 2 528 74 01 http://www.ansell.eu E-mail info.europe@ansell.com
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.