Dokumentation
Ose_directory e-shot
2685 Visninger •Checkline II maintenance manual
3054 Visninger •Chemsplash Pro WD40 Test
2412 Visninger •Ergonomi 2006
2968 Visninger •Ose_directory Suspension harness
2726 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3432 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3193 Visninger •VISOR Installation steps
3979 Visninger •Desinfektionsprodukter med effekt på Coronavirus 2019-nCoV
2970 Visninger •Hearing protection 3M
2522 Visninger •Statistik for arbejdsmiljø 2014
2980 Visninger •LOTO_GuideBook_Europe_English
2528 Visninger •Remote area lighting system
2289 Visninger •Isol8 - The Ultimate Absorbent for Spills
2303 Visninger •Magazine Arbejdsmiljø - november 2012
2477 Visninger •KEE_DOME_MINI
2385 Visninger •TDS Speedglas 9100
2561 Visninger •The Pocketbook of Lean Visuals
2564 Visninger •Instructional video Sign holder
1847 Visninger •PREMARK installation manual
2517 Visninger •D-S CSR Håndbog
16979 Visninger •Find handskestørrelse - størrelsesguide for handsker
9989 Visninger •3M jupiter manual
6105 Visninger •9100 Manual
5047 Visninger •EN 388 nye mærkninger forklaring
4719 Visninger •D-S 70 års om os brochure
4696 Visninger •Forklaring af den nye EN ISO 374 kemikalier norm
4635 Visninger •Faldsikring flyer
4248 Visninger •Hvordan du kalibrere en 3M Jupiter luftstrøms enhed
4017 Visninger •VISOR Installation steps
3979 Visninger •Guide til valg af åndedrætsværn
3551 Visninger •TR-300 Bruger manual
3519 Visninger •VARMEX 2000 Fordele
3495 Visninger •Procurement Guide annonce Health and Safety International - Europe's magazine for employee protection and personal protective equipment
3432 Visninger •3M TR 300 PAPR training video
3401 Visninger •Demonstration af velcro strop til montering/påsætning af gasdetektor på faldsikringssele
3193 Visninger •Procedure for iklædning af engangsbeklædning
3165 Visninger •3020 Solcreme SPF 30 datablad
3140 Visninger •3M 8825+ 8835+ 06936+ 1895V+ BSI CE-Cert_(CE_705688_(Iss_30_09_2019))
3133 Visninger •Aura_Gen_3_BSI_Cert_(CE_681745_(Iss_07_10_2019)
3094 Visninger •D_1C7600_DSx_Standard_644512_6
Visninger | |
---|---|
404 | Totale visninger |
0 | Medlemmer visninger |
404 | Offentlige visninger |
Del via email
Venligst login for at dele dette document via email.
Indlejr på din hjemmeside
2. Head Office Factory Tel: +46 10 484 87 00 Tel: +46 10 484 87 00 Visiting address: Visiting address: Stockholmsvägen 33 Västergatan 4 SE-181 33 Lidingö SE-341 50 Lagan www.srsafety.com Batteries are transported either together with the fans or as spare parts. Transport We guarantee and can demonstrate that each battery/cell is compliant with the requirements and criteria of the UN (United Nations) test manual, Part III, Section 38.3, Revision 5, Amendment 1. Lithium-ion batteries in equipment Lithium-ion batteries Road UN 3481 Special provision 188, ADR/ADR-S 2015 UN 3480 Special provision 188, ADR/ADR-S 2015 Sea UN 3481 Special provision 188, IMDG Code 37-14 UN 3480 Special provision 188, IMDG Code 37-14 Air UN 3481 Packaging instruction 967, Section II, DGR 57 UN 3480 Packaging instruction 965, Section II, DGR 57 Transport of lithium-ion batteries Transport of nickel-metal hydride batteries Nickel-metal hydride in equipment Nickel-metal hydride batteries Road Not covered by ADR Not covered by ADR Sea UN 3496 Special provision 963, IMDG Code 37-14 (Only Hazardous Goods if more than 100 kg) UN 3496 Special provision 963, IMDG Code 37-14 (Only Hazardous Goods if more than 100 kg) Air ”Not Restricted” Special provision A199, DGR 57 ”Not Restricted” Special provision A199, DGR 57 Product leaflet Product Model No. Ordering No. Battery, STD SR 501 R06-0108 Battery, STD SR 701 R06-0708 Battery, HD SR 502 T06-0101 Battery, HD SR 502 T06-0115 Battery, EX SR 501 EX R06-2002
1. Head Office Factory Tel: +46 10 484 87 00 Tel: +46 10 484 87 00 Visiting address: Visiting address: Stockholmsvägen 33 Västergatan 4 SE-181 33 Lidingö SE-341 50 Lagan www.srsafety.com Product leaflet Sundström’s battery-powered SR 500 and SR 700 fans use lithium-ion batteries. The SR 500 is available with two battery options, a standard (STD) battery and a heavy duty (HD) battery. Sundström’s battery-powered SR 500 EX fans use a nickel-metal hydride battery. These batteries are rechargeable and can be fully charged in approx. 2 hours. Discard used batteries at a recycling station. Product Model No. Ordering No. Battery, STD SR 501 R06-0108 Battery, STD SR 701 R06-0708 Battery, HD SR 502 T06-0101 Battery, HD SR 502 T06-0115 Battery, EX SR 501 EX R06-2002 Product description Technical specification SR 501, SR 701 SR 502 SR 501 EX Cell type Lithium-ion Lithium-ion Nickel-metal hydride Nominal cell voltage 14.8 V 14.8 V 13.5 V Capacity 2.2 Ah 3.6 Ah 2.1 A h Energy density 33 Wh 53 Wh 28 Wh Energy density/cell 8.25 Wh 6.62 Wh 2.6 Wh No. of cells per battery 4 8 11 Weight SR 501: 280 g SR 701: 235 g 410 g 605 g Service temperature -10 - +55°C, < 90% RH -10 - +55°C, < 90% RH -10 - +40°C, < 90% RH Storage temperature -20 - +40°C, < 90% RH -20 - +40°C, < 90% RH -20 - +40°C, < 90% RH P06T-010218 Rev 05 20161222 SR 701 SR 501 EX SR 501/502
Relaterede produkter
To install this Web App in your iPhone/iPad press and then Add to Home Screen.